Digilib Perpustakaan Universitas Riau

Tugas Akhir, Skripsi, Tesis dan Disertasi Mahasiswa Universitas Riau

  • Beranda
  • Informasi
  • Berita
  • Bantuan
  • Pustakawan
  • Pilih Bahasa :
    Bahasa Arab Bahasa Bengal Bahasa Brazil Portugis Bahasa Inggris Bahasa Spanyol Bahasa Jerman Bahasa Indonesia Bahasa Jepang Bahasa Melayu Bahasa Persia Bahasa Rusia Bahasa Thailand Bahasa Turki Bahasa Urdu

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Image of Analisis Perhitungan Energy Balance Heat Exchanger Shell And Tube Dan Mass Balance Pemakaian Soft Water Di Bleaching Fiberline #1
Penanda Bagikan

CD Tugas Akhir

Analisis Perhitungan Energy Balance Heat Exchanger Shell And Tube Dan Mass Balance Pemakaian Soft Water Di Bleaching Fiberline #1

Owen Aloysius / 2007036564 - Nama Orang;

ABSTRACT
Heat exchangers 411E104 and 411E237 are types of shell and tube heat exchangers. The shell part is filled with the cold medium, which is soft water, and the tube part is filled with the hot medium, which is black liquor. Soft water is a type of water with low levels of calcium and magnesium, while black liquor is the residual liquor after the cooking process. Soft water is purchased from the Water Treatment Plant department at a high price of US$0.046 per 1 m3, so the usage of soft water needs to be taken into account. The purpose of this study is to calculate and determine the required (theoretical) flow of soft water for heat exchangers 411E104 and 411E237 according to the parameters that need to be controlled, as well as to understand the mass balance of soft water usage. The methods employed in this study include literature review, field observation, data collection, discussions, data processing, and drawing conclusions and recommendations. The calculation of the theoretical flow of soft water is done using the energy balance equation. Based on the calculations conducted, the theoretical flow of soft water for heat exchangers 411E104 and 411E237 is determined to be 112.31 l/s and 123.65 l/s, respectively. The average mass balance analysis of soft water usage from February 1-11, 2023, indicates an excess production of 20,261.64 m3/day. The conclusion drawn from this study is that the average actual flow of soft water from February 1-11, 2023, is higher than the theoretical flow, and the mass balance of soft water is not balanced.
Keywords: heat exchanger, soft water, mass balance


Ketersediaan
#
Perpustakaan Universitas Riau 2007036564
2007036564
Tersedia
Informasi Detail
Judul Seri
-
No. Panggil
2007036564
Penerbit
Pekanbaru : Universitas Riau – Fakultas Teknik – TEKNOLOGI PULP DAN KERTAS., 2023
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
2007036564
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
-
Subjek
TEKNIK KIMIA
Info Detail Spesifik
-
Pernyataan Tanggungjawab
DAUS
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • COVER
  • DAFTAR ISI
  • ABSTRAK
  • BAB I PENDAHULUAN
  • BAB II TINJAUAN PUSTAKA
  • BAB III METODE PENELITIAN
  • BAB IV HASIL DAN PEMBAHASAN
  • BAB V PENUTUP
  • DAFTAR PUSTAKA
  • LAMPIRAN
Komentar

Anda harus masuk sebelum memberikan komentar

Digilib Perpustakaan Universitas Riau
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik
Kemana ingin Anda bagikan?