ABSTRACT
This report describes a resonant L-C inverter protection device for high
voltage generation. This inverter is connected to a fly-back transformer as a step
up transformer to 22 kV.The tool is designed to protect the overcurrent on the
inverter side. The tool will work if the load current entering the high-voltage
flyback transformer is >5.0 A. The measured voltage at the inverter mosfet output
to the flyback transformer when the normal load is 8.7V and when the overload is
0V. Comparison of measurements between Ampere meter and Current sensor
SCT-013 on the tool has an error of
Tidak tersedia versi lain