Pengaruh Cara Dan Perbandingan Lama Perawatan Pembasahan Terhadap Kuat Tekan Beton K-250

TESA TIARA PUSPITA / 1907024617 - Nama Orang;

ABSTRACT
The compressive strength of concrete is influenced by many things, including the constituent materials, mix design, workmanship, and maintenance. The purpose of this treatment is to prevent or reduce water loss/evaporation from inside the concrete which is still needed for the continuation of the hydration process so that the optimization of concrete strength can be achieved close to the strength that has been planned. This study aims to determine the effect of the method and duration of wetting treatment on the compressive strength of concrete that is not treated and treated with wetting. The design concrete is K-250 with a cylindrical specimen with a height of 30 cm and a diameter of 15 cm. Compressive strength testing was carried out at 28 days. The optimum compressive strength is produced with a curing time of 28 days resulting from the treatment by immersion in water which has an average of 306.14 Kg/Cm². Concrete placed in the room without treatment has an average compressive strength value of 190.50 Kg/Cm². The compressive strength value of concrete by means of wet sack treatment has an optimum compressive strength of 264.40 Kg/Cm². The results showed that the highest compressive strength was produced in the immersion treatment in the tub, and in the treatment covered with wet sacks it had a compressive strength that was not far from the predetermined plan, whereas without treatment it did not reach the planned compressive strength.
Kata Kunci : Wetting treatment, compressive strength, effect of method and duration of treatment.


Ketersediaan
#
Perpustakaan Universitas Riau 1907024617
1907024617
Tersedia
Informasi Detail
Judul Seri
-
No. Panggil
1907024617
Penerbit
Pekanbaru : Universitas Riau – Fakultas Teknik – Teknik Sipil., 2023
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
1907024617
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
-
Subjek
TEKNIK SIPIL
Info Detail Spesifik
-
Pernyataan Tanggungjawab
DAUS
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • COVER
  • DAFTAR ISI
  • ABSTRAK
  • BAB I PENDAHULUAN
  • BAB II LANDASAN TEORI
  • BAB III METODE PENELITIAN
  • BAB IV HASIL DAN PEMBAHASAN
  • BAB V KESIMPULAN DAN SARAN
  • DAFTAR PUSTAKA
  • LAMPIRAN
Komentar

Anda harus masuk sebelum memberikan komentar

Digilib Perpustakaan Universitas Riau
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

As a complete Library Management System, SLiMS (Senayan Library Management System) has many features that will help libraries and librarians to do their job easily and quickly. Follow this link to show some features provided by SLiMS.

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik
Kemana ingin Anda bagikan?