CD Tugas Akhir
Pengaruh Perendaman Beton Pasca Bakar Dengan Variasi Faktor Air Semen Terhadap Kuat Tekan Beton Pada Suhu 800°C
Penetration thermal post-combustion occurs in concrete can alter the chemical properties of concrete and of course, this directly affects the physical properties of the concrete is concrete performance in receiving compressive strength. This study was conducted with a sample in the form of a cube 15 cm x 15 cm x 15 cm with a W/C water factor variation Wateramong others are0:45, 0.5, and 0.6 0:55.Combustionperformed at a temperatureof 800°Cwith aburningtime of1hourThe percentagedecrease inthe compressive strengthof concretepost-combustion without soakinginconsecutiveconcretenormal is 9.5 % , 13.8 %, 16.5 % and 21.0` %.While on theconcretepost-combustion soakingfor 3daysincreasedcompressive strengthbut the increaseisnot significanthappens4.5 % , 3.3 %, 2.6 % and 0.8 %.From this study it appears that variations FAS no significant impact on reducing the strength of concrete and concrete compressive strength increase with immersion
Keywords: W / C,fire, compressive strength, immersion
Tidak tersedia versi lain