CD Skripsi
Analisis Dan Simulasi Perubahan Kharakteristik Parameter Generator Induksi 3 Fasa Akibat Variasi Pembebanan
ABSTRACT
An induction machine can be operated as a generator or as a motor so that it can be called an induction generator. In a three-phase induction generator with a single-phase output, the loading that occurs greatly affects the value of the output voltage and efficiency. The characteristics of the generator are largely determined by the parameters in the induction generator. The research method used to look at these parameter values is by simulating and analyzing matlab simulink by giving an induction generator a load variation of 2 kW, 3 kW, and 4 kW and then analyzing the values of voltage, current, frequency and rotational speed. In order for an induction generator to produce a balanced and constant voltage, a three-phase induction generator must be connected with the correct rated capacitor. From this research, when the induction generator is given a variation of load, it can be seen that the greater the load on the three-phase induction generator, the smaller the voltage produced, the current increases, the rotational speed decreases, and the frequency decreases.
Keywords: induction generator, current, voltage, frequency.
Tidak tersedia versi lain