ABSTRACT An undervoltage supply below the nominal value can significantly affect the performance of a 3-phase induction motor, especially under load conditions. This study aims to analyze the effect of an undervoltage supply on a 3-phase induction motor in the Electrical Energy Conversion Laboratory at Universitas Riau. The experiment was conducted with voltage variations of 380 V, 360 V, 340 …