CD Skripsi
Interpretasi Potensi Air Bawah Tanah Dengan Menggunakan Metode Geolistrik Aturan Schlumberger Dan Geokimia Di Kelurahan Pebatuan Kecamatan Tenayan Raya Kota Pekanbaru
Increased population growth and development in the Pebatuan Village area where
the availability of groundwater is not evenly distributed in each area. This
research aims to determine the depth of groundwater and groundwater quality.
Measurements using the Schlumberger configuration geoelectric method on two
tracks, with the length of each track 100 m. Based on the results of data
processing, the first path of the aquifer layer is at a depth of 12-60 meters and a
thickness of 48 meters with a resistivity value of 96-113.46 m. on the second
trajectory the aquifer layer is found at a depth of 11-65 meters and a thickness of
54 meters with a resistivity value of 171-196.33 m. The conclusion from the
determination of the presence of underground water using the geoelectric method
of the Schlumberger configuration obtained three layers with different
resistivities, underground water was found in the third layer. Underground water
that is taken is water from the wells of residents in the research area. Underground
water samples were tested with parameters pH, TDS, and Turbidity. Underground
water cannot be consumed from the results of the water quality test with the
parameters previously mentioned if referring to the Regulation of the Minister of
Health of the Republic of Indonesia Number 492 of 2010 because the pH obtained
is < 6.5 or is acidic.
Keywords : Underground Water, Samples, Geoelectrics, Schlumberger
Configuration
Tidak tersedia versi lain